Página 1 dos resultados de 1694 itens digitais encontrados em 0.002 segundos

‣ EXERGOECONOMIC COMPARISON OF ABSORPTION REFRIGERATION SYSTEMS INCLUDING A HIBRID ABSORPTION-EJECTO COMPRESSION CHILLER

JARAMILLO, Juan Carlos Burbano; PELLEGRINI, Luiz Felipe; OLIVEIRA JR., Silvio De
Fonte: UNIV NAC COLOMBIA, FAC NAC MINAS Publicador: UNIV NAC COLOMBIA, FAC NAC MINAS
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
37.220156%
The study of absorption refrigeration systems has had increasing importance in recent years due to the fact that the primary energy that is used in an absorption system can be heat available from a residual source or even a renewable one. Therefore, these systems not only use energy that would be rejected by the environment, but also they avoid the consumption of expensive fossil or electrical energies. The production cost of the mechanical work necessary to obtain a kW of refrigeration for mechanical compression cycle is normally higher than the cost for recovering the needed heat to obtain the same kW in an absorption cycle. Also, the use of these systems reduces impact on the environment by decreasing the emission of CO(2). We intend to show the performance of a hybrid absorption-ejecto compression chiller compared to conventional double- and single-effect water/lithium bromide systems, by means of an exergetic and exergoeconomic analysis of these configurations in order to calculate the exergy-based cost of a final product. The vapor compression refrigeration system is included in the results, as a comparisson to the performance of the absorption refrigeration systems analyzed.

‣ Sazonalidade, refrigeração e diferentes tipos de recobrimento na conservação pós-colheita de estacas de cordiline (Cordyline rubra Hügel).; Seasonality, refrigeration and different types of coating on the postharvest conservation of Cordyline rubra Hügel cuttings.

Sakamoto, Nelson Mamoru
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 06/06/2005 Português
Relevância na Pesquisa
37.220156%
O mercado mundial de floricultura gera um fluxo de quase US$ 7bilhões anuais, atualmente concentrado em países como Holanda, Alemanha, Itália, Colômbia, Costa Rica, Equador, Quênia, Tailândia, Malásia, Israel e EUA. O Brasil ainda contribui pouco, aproximadamente 0,3% do total, sendo a participação brasileira concentrada na exportação de mudas, bulbos, flores e folhagens tropicais. O Brasil possui grande potencial exportador de flores e plantas ornamentais através da organização dos produtores, profissionalização do setor, apoio governamental e desenvolvimento técnico. O emprego de técnicas simples de armazenamento poderia viabilizar o transporte por modais que não o aéreo, reduzindo custos e podendo prolongar a vida útil dos produtos, criando um diferencial de qualidade em relação aos concorrentes. Este trabalho compara cinco diferentes tipos de recobrimento em estacas de Cordyline rubra Hügel (película amilácea, pasta de parafina no ápice, pasta de parafina no ápice e vermiculita umedecida na base, saco plástico ou sem recobrimento), sazonalidade (estacas coletadas durante primavera ou outono), dois ambientes de armazenamento (ambiente refrigerado a 10ºC ou temperatura ambiente 22-32ºC) e diferentes períodos de armazenamento (30...

‣ Estudo de confiabilidade de compressores alternativos semi-herméticos de sistemas de refrigeração.; Reliability study of reciprocating compressors of refrigeration systems.

Bassetto, Izeds Felipe Facchini
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 27/03/2007 Português
Relevância na Pesquisa
37.148538%
Sistemas de refrigeração são sistemas reparáveis. Isto significa que os componentes destes sistemas podem sofrer manutenção várias vezes durante a vida útil do sistema como um todo. Em sistemas de refrigeração o mais conhecido é o que opera com ciclo por compressão de vapor. Neste ciclo, o compressor é o equipamento mais complexo e de maior custo. Dessa forma, deve-se tomar especial cuidado, pois além de problemas como desgaste e falta de lubrificantes, ele está sujeito a sofrer danos decorrentes do funcionamento incorreto ou falho de todos os outros componentes. Dentro dos compressores existentes, o compressor alternativo pode ser comercialmente considerado o cavalo de batalha da refrigeração industrial, dominando a faixa de capacidades inferiores a 300 kW (85 TRs). O compressor alternativo também pode ser utilizado, com vantagens, quando o controle de capacidade se faz necessário, através do procedimento de desativação dos cilindros. Este compressor possui a possibilidade de manutenção no campo de, praticamente, qualquer item construtivo. O termo confiabilidade vem do inglês "reliability" que é a probabilidade de um item poder desempenhar sua função requerida, por um intervalo de tempo estabelecido, sob condições definidas de uso. Testes de confiabilidade possibilitam...

‣ Simulação transiente de um sistema de refrigeração doméstico: análise paramétrica; Transient simulation of a domestic refrigeration system: parametric analysis

Rangel, Sergio de Camargo
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 07/12/2007 Português
Relevância na Pesquisa
37.350754%
No presente trabalho são apresentados resultados de simulação numérica transiente de um sistema de refrigeração doméstico de compressão a vapor considerando o procedimento descrito por JAKOBSEN (1995). O modelo matemático empregado se baseia num sistema de equações algébrico-diferenciais (EAD) de primeira ordem, obtido a partir do balanço de energia nos diferentes componentes do sistema de refrigeração, e de algumas outras relações necessárias para simular o comportamento global do sistema de refrigeração. O sistema de equações resultante é resolvido numericamente no software livre WinDali, da Universidade Técnica de Dinamarca. Dito software permite resolver sistemas de EADs que apresentam descontinuidades matemáticas usando o método de Runge- Kutta de quarta ordem. O modelo matemático empregado permite calcular a eficiência do sistema de refrigeração, predizer o consumo de energia, caracterizar termodinamicamente o sistema de refrigeração e suas interações, e descrever quantitativamente as perdas termodinâmicas (geração de entropia) do sistema funcionando em regime de operação. Esses resultados são obtidos em função da estratégia de controle do compressor, eficiência do compressor e do dimensionamento dos diferentes componentes do sistema de refrigeração. Os resultados comprovam que o modelo matemático e o programa computacional empregados permitem descrever corretamente o comportamento de um sistema de refrigeração doméstico...

‣ Projeto de um sistema de refreigeração industrial com "Set-Point" variável.; Design of industrial refrigeration systems with variable set-point.

Salvador, Francisco
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 04/08/1999 Português
Relevância na Pesquisa
37.274307%
Os sistemas térmicos operam na maior parte do tempo fora de suas condições nominais de projeto. Nos sistemas de refrigeração industrial, a operação com carga térmica parcial ocorre em função de diversos fatores e o consumo de energia apresenta grande variação em função do ciclo de operação. Neste trabalho é proposta a otimização energética dos sistemas frigoríficos por compressão a vapor através da operação com regime variável para o ciclo frigorífico, especificamente através da operação com set-point de temperatura de evaporação variável. Para tanto é desenvolvido um modelo matemático para simulação dinâmica de um sistema de refrigeração industrial por compressão a vapor com refrigerante amônia (R-717) para o congelamento de alimentos composto basicamente de túnel de congelamento por circulação forçada de ar, evaporador com recirculação de líquido, reservatório de líquido a baixa pressão, compressores parafuso e condensador evaporativo atmosférico. São analisados através de simulação dois métodos para a variação do setpoint de temperatura de evaporação: a máxima temperatura de evaporação admissível e a minimização da potência no compressor. Os dois métodos são comparados ao sistema de controle de capacidade atualmente utilizado em instalações industriais.; Thermal systems operate most of the time at off-design conditions. In industrial refrigeration systems...

‣ Dimensionamento e avaliação do ciclo de refrigeração de sistema de climatização automotivo.; Sizing and evaluation of an automotive climate system refrigeration cycle.

Santos, Eduardo Oliveira dos
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 02/09/2005 Português
Relevância na Pesquisa
37.402136%
O ser humano consome grandes quantidades de energia para satisfazer as suas necessidades de conforto. Dentro do setor automotivo, depois da energia consumida com a mobilidade em si, o ar condicionado é o maior consumidor. O sistema de climatização para aplicações automotivas tem características particulares, diferentes de sistemas de climatização para outros ambientes. Em uma aplicação automotiva a variação de condições é bastante significativa, como por exemplo, a carga solar que é imposta, a velocidade do veículo, umidade do ar, as temperaturas interna e externa, variação do número e da posição dos ocupantes no interior do veículo, diferentes regimes de rotação e carga do motor, etc. O sistema deve, portanto, ser projetado para funcionar sob todas estas condições e propiciar condições de conforto térmico com o menor consumo de energia. No presente trabalho o objetivo é o projeto e a simulação de um ciclo de refrigeração que atenda aos requerimentos de carga térmica para um automóvel compacto em um ensaio específico realizado em túnel de vento. A partir da carga térmica, o ciclo de refrigeração é dimensionado seguindo-se o procedimento de projeto, que engloba o dimensionamento dos componentes principais como compressor...

‣ Avaliação de um sistema de refrigeração por adsorção para produção de gelo, operando diferentes tipos de ciclo com baixas temperaturas de geração.; Evaluation of a system of refrigeration for adsorção for ice production, operating different types of cycle with low temperatures of generation.

Rogerio Gomes de Oliveira
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 02/04/2004 Português
Relevância na Pesquisa
37.274307%
Neste trabalho propôs se construir o protótipo de um sistema de refrigeração por adsorção para produzir gelo, que oferecesse flexibilidade quanto aos ciclos frigoríficos operados e que pudesse utilizar diferentes fontes de calor para regenerar o adsorvente. Para construir este protótipo, primeiramente, comparou-se alguns adsorventes e adsorvatos em relação a certas propriedades e características desejáveis em sistemas de refrigeração por adsorção e escolheu-se como refrigerante a amônia. Utilizando-se a equação de Dubinin- Astakhov com os parâmetros obtidos a partir da caracterização do equilíbrio termodinâmico do par carvão ativado/amônia, pode-se estimar a variação da concentração de refrigerante no leito adsortivo durante os ciclos frigoríficos. A seguir, modelou-se um sistema de refrigeração por adsorção com possibilidade de operar diferentes tipos de ciclo frigorífico. Resolvendo-se numericamente as equações do modelo em diferentes condições de operação e de projeto do sistema, concluiu-se que a utilização do ciclo em duplo estágio com recuperação de vapor de refrigerante produz maior potência de refrigeração útil e C.O.P. (Coeficiente de Desempenho) que a utilização dos demais ciclos...

‣ Aperfeiçoamento de um simulador de sistemas de refrigeração de absorção agua-amonia e sua aplicação para projeto de um sistema movido a gas de escape de motor diesel; Development of ammonia-water absorption refrigeration systems simulator and its application in a project of a system moved by exhaust gases of diesel engine

Patricia Akemi Makiyama
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 28/11/2008 Português
Relevância na Pesquisa
37.316685%
Este estudo apresenta o desenvolvimento de um programa pré-existente de simulação de um sistema de refrigeração por absorção água-amônia que utiliza como fonte de energia os gases de exaustão de um motor diesel de um grupo diesel-gerador. O projeto foi executado em quatro etapas. Um dimensionamento inicial dos diversos componentes envolveu relações puramente termodinâmicas, e baseou-se no arbítrio de diferenças de temperatura nos diversos trocadores de calor e algumas condições operacionais e ambientais, como capacidade de refrigeração e temperatura de entrada da água de resfriamento nos condensadores e absorvedor. Obteve-se, assim, o porte de cada equipamento do sistema de refrigeração em termos de parâmetros, tais como os coeficientes globais de transferência de calor multiplicado pelas áreas de cada componente ou a efetividade multiplicada pela mínima capacidade térmica horária. Na segunda etapa, foi feito o detalhamento construtivo de cada componente do sistema com o intuito de se chegar o mais próximo possível aos resultados do projeto inicial. Foram introduzidas as relações para o cálculo de transferência de calor de cada componente do sistema, o cálculo dos respectivos coeficientes de transferência de calor e as perdas de cargas relevantes ao cálculo da potência elétrica auxiliar demandada pelo sistema. Uma vez definida a configuração inicial de um sistema de refrigeração por absorção específico...

‣ Hyperbaric storage of soup and comparison with refrigeration; Conservação de sopa a pressão elevada e comparação com refrigeração

Moreira, Sílvia Alexandra Monteiro
Fonte: Universidade de Aveiro Publicador: Universidade de Aveiro
Tipo: Dissertação de Mestrado
Português
Relevância na Pesquisa
37.274307%
The aim of this work was to investigate if hyperbaric storage, using high hydrostatic pressure, is effective in delaying ready-to-eat food products microbial and physicochemical spoilage allowing extending its shelf-life, with no need for refrigeration. Inicially, the hyperbaric storage of a ready-to-eat carrot soup was studied and compared to refrigeration. Soup was stored at diferente time (4 and 8 h), temperature (4, 25 and 30 ºC), and pressure (0.1, 100 and 150 MPa) conditions. In addition, were also performed tests in an industrial equipment with two real commercial products, Caldo verde and Bacalhau com natas that were stored for 12 h at different pressures (50, 100 and 150 MPa) at room temperature (~21 ºC). For both cases, microbial loads (total aerobic mesophiles, Enterobacteriaceae and yeast and moulds) and physicochemical parameters such as pH, titratable acidity, reducing sugars and colour, were compared with the controls at atmospheric pressure at the same temperature. Hyperbaric storage resulted in similar to better results when compared to refrigeration, since 100 MPa resulted in microbial growth inhibition, while for storage under 150 MPa microbial inactivation occured. Higher pressure (150 MPa) and a longer storage period (8 h for laboratorial scale...

‣ Experimental mapping of the thermodynamic losses in vapor compression refrigeration systems

Gonçalves,Joaquim M.; Melo,Cláudio; Hermes,Christian J. L.; Barbosa Jr.,Jader R.
Fonte: Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM Publicador: Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2011 Português
Relevância na Pesquisa
37.274307%
The present study introduces a methodology for mapping the thermodynamic losses of vapor compression refrigeration systems which consists of a theoretical model that splits the coefficient of performance into four terms: (i) the coefficient of performance of an ideal cycle (Carnot), (ii) the efficiency of a real cycle running with an ideal compressor, (iii) the compression efficiency of a real compressor, and (iv) the cycling efficiency. In addition, measurements of the relevant variables at several positions along the refrigeration loop are also required, generating performance data not only for the whole unit but also for each one of the system components. The proposed methodology points out the thermodynamic losses of the refrigeration system, identifying opportunities for energy performance improvement. In addition, the methodology is suitable for comparing different refrigeration systems with respect to the same thermodynamic baseline. Albeit the methodology was originally developed for household refrigerators, it can be easily extended to any kind of vapor-compression refrigeration systems.

‣ Thermodynamic Evaluation of a Two Stages Compression Refrigeration System Integrated to an Absorption System

Corr??a, Gilberto Arejano; Souza, Jeferson Avila; Hernandez, Carlos Prentice; Rocha, Luiz Alberto Oliveira
Fonte: Universidade Federal do Rio Grande Publicador: Universidade Federal do Rio Grande
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
37.220156%
This work is based on the principles of administration, with technical and economic data from a frigorific fishing industry, at analyzing the convenience of integrating to the existing refrigeration system (by vapor compression) a refrigeration system by absorption. By comparing the existing system, and this one integrated with absorption, it was applied a thermodynamic evaluation for a mean frigorific output of 33.43 kW. The profitable result obtained from this evaluation indicated the feasibility of the integrated refrigeration system, with an operation time of up to 25.64 %, less than the existing refrigeration system, enabling a lower amount of time for investment return than five years. In the evaluation, they were compared the energetic model, associating energy and the operation cost. The highest profitability of integrated system shows, for the system applied in the industry, that by applying such system it contributes to lower the operations costs, with further results of increased in the product offer, and competitiveness in marketing frigorific items.

‣ Análise de desempenho do tubo capilar num sistema de refrigeração de pequeno porte com variação da velocidade do compressor; Analyze performance of capillary tube in small refrigeration system varying the speed compressor

Alegrias, Juan Gabriel Paz
Fonte: Universidade Federal de Uberlândia Publicador: Universidade Federal de Uberlândia
Tipo: Dissertação
Português
Relevância na Pesquisa
37.220156%
A necessidade de reduzir o consumo de energia nos sistemas de refrigeração e condicionamento de ar é uma das prioridades da indústria da refrigeração. Isto tem incentivado o desenvolvimento de sistemas frigoríficos mais eficientes e que ofereçam um melhor desempenho. Neste contexto, aumenta a importância da aplicação de novas tecnologias que permitam um conhecimento mais profundo destes sistemas e a melhora e otimização dos processos de resfriamento. Portanto, com o monitoramento e controle das condições de operação de um sistema de refrigeração por compressão de vapor de pequeno porte para resfriamento de líquido, que opera com compressor de velocidade variável, tubo capilar como elemento de expansão e utiliza R134a como fluido refrigerante, este trabalho; estuda o comportamento do sistema de refrigeração e apresenta uma análise da influência da mudança das dimensões do tubo capilar e da velocidade de rotação do compressor sob o ponto de vista do desempenho e o consumo energético. Os resultados obtidos, produto da análise de superfícies de resposta, mostram como uma ótima combinação de critérios resulta num melhor rendimento do sistema. ____________________________________________________________________________________ ABSTRACT; The need to reduce energy consumption in refrigeration and air conditioning is a priority for the refrigeration industry. This has encouraged the development of refrigeration systems more efficient and offer better performance. In this context...

‣ Time-dependent effect of refrigeration on viscosity and conversion kinetics of dental adhesive resins

Faria e Silva, Andr?? Luis; Piva, Evandro; Moraes, Rafael Ratto de
Fonte: Medknow Publications Publicador: Medknow Publications
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
37.220156%
Objectives: This study evaluated the effect of refrigeration at 4oC and post-refrigeration times (immediate, 5, 10, 15, or 20 min) on the viscosity and conversion kinetics of adhesive bonding resins. Methods: Scotchbond Dual-Cure (3M ESPE) and Clearfil SE Bond (Kuraray) were tested. Control samples were kept at 25oC for 24 h. At each post-refrigeration time, the temperature was checked with a K-type thermocouple. Viscosity measurements as a function of temperature were performed using a cone-plate viscometer. Real-time polymerization was monitored by infrared spectroscopy. Degree of conversion (DC) was calculated for each second during polymerization, and the rate of polymerization analyzed. Data were separately submitted to two-way ANOVA and Tukey???s test (P<.05). Results: Clearfil presented faster increase in temperature after exposure to room temperature than Scotchbond. A continuous decrease in viscosity (Pa.s) was observed for both Scotchbond (0.49, 0.34, 0.30, 0.26, 0.23, 0.23) and Clearfil (0.38, 0.37, 0.34, 0.25, 0.24, 0.22). For Scotchbond, higher final DC was detected for the control (62.7%) compared with the immediate (53.3%) and 5 min (54.7%) groups. For Clearfil, the control sample (81.4%) showed higher DC than all refrigerated groups (68.8??? 69.5%). Clearfil always showed significantly higher DC than Scotchbond. Conclusions: Refrigeration presented a significant time- and material-dependent effect on the viscosity and polymerization kinetics of the bonding resins. Under clinical conditions...

‣ Study of activated carbon/methanol adsorption refrigeration tube and system integration.

Zhao, Yongling
Fonte: Universidade de Adelaide Publicador: Universidade de Adelaide
Tipo: Tese de Doutorado
Publicado em //2011 Português
Relevância na Pesquisa
37.274307%
Solid adsorption refrigeration systems are attracting much research interest because they have numerous advantages, such as using low grade thermal energy and being environment friendly. In recent decades many efforts have been put into developing various prototypes. The adsorption refrigeration tube (ART) is one such development. Through better system integration, a module consisting of a number of individually working ARTs can achieve significant refrigeration capacity, which may solve the vacuum leaking problem that besets large adsorption systems. In order to propose a feasible ART, this thesis undertakes a study of adsorptive properties of three types of activated carbon/methanol working pairs and modelling of the adsorption refrigeration cycle. In this examination of adsorptive properties, three activated carbon samples, Calgon 207C, 207EA and WS-480, were used to test and determine their pressure-temperature-concentration (P−T−x) relationship with methanol as the adsorbate. Based on the experimental data, three adsorption state equations, Langmuir equation, Freundlich equation and Dubinin-Astakov (D-A) equation, were compared in terms of their agreement with experimental data and their format impact on calculating coefficient of performance (COP) and refrigeration output (Qr)...

‣ Controle preditivo baseado em modelo neuro-fuzzy de sistemas não-lineares aplicado em sistema de refrigeração = : Model predictive control based on neuro-fuzzy nonlinear systems applied to a refrigeration plant; Model predictive control based on neuro-fuzzy nonlinear systems applied to a refrigeration plant

Ivan Carlos Franco
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 03/07/2012 Português
Relevância na Pesquisa
37.274307%
Os sistemas de refrigeração estão presentes em diferentes ramos da indústria e caracterizam-se como grandes consumidores de energia com considerável comportamento não-linear. Inúmeros trabalhos vêm sido desenvolvidos para promover a redução dos gastos energéticos e a minimização dos efeitos das não-linearidades nestes sistemas. A aplicação da automação e do controle de processos, particularmente o uso de técnicas avançadas de controle, são estratégias amplamente utilizadas para esta finalidade. O Controle Preditivo baseado em Modelos (MPC) é capaz de estabilizar processos onde há não-linearidades, sendo promissora a sua aplicação em sistemas de refrigeração. Neste trabalho, foi desenvolvido um SIStema de MOnitoramento e Controle Avançado para Refrigeração (SISMOCAR) capaz de monitorar, em tempo real, através da comunicação OPC (OLE for Process Control), todas as variáveis envolvidas no ciclo de refrigeração e também realizar o controle das variáveis de interesse. Modelos Takagi-Sugeno (SISO) para a predição das temperaturas de evaporação (Te) e do fluido secundário (Tp) foram desenvolvidos e validados, a partir da técnica ANFIS (Adaptative Network based Fuzzy Inference Systems), com análise de desempenho baseado no cálculo do VAF (Variance accounted for). Os modelos Takagi-Sugeno validados foram utilizados como base para Controladores Preditivos...

‣ Otimização de ciclos de refrigeração para a produção de gás natural liquefeito; Optimization of refrigeration cycles for the production of liquefied natural gas

Thalles Allan Andrade
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 26/08/2014 Português
Relevância na Pesquisa
37.220156%
Por se tratar de um combustível fóssil menos emissor de gás carbônico ao meio ambiente do que outros combustíveis, a demanda mundial de gás natural para sua utilização como fonte energética tem aumentado nos últimos anos. No entanto, quando a quantidade requerida de importação do gás natural é alta e é grande a distância entre os países fornecedores e compradores, o transporte do gás por meio de gasodutos torna-se inviável, acarretando na necessidade de produção de gás natural liquefeito. Ao se liquefazer a uma temperatura próxima a -160 °C, o volume do gás natural é reduzido em até 600 vezes, permitindo ser transportado a grandes distâncias por meio de embarcações especiais. Na liquefação do gás natural estão envolvidos ciclos de refrigeração que podem ser utilizados por diferentes rotas. Os principais tipos de ciclo de refrigeração são o ciclo de compressão de vapor e o ciclo de absorção. Nesse trabalho, foram simulados no programa Aspen HYSYS, versão 7.3, os ciclos cascata e APCI para a produção de GNL, que utilizam ciclos de refrigeração por compressão de vapor. O coeficiente de desempenho global do ciclo APCI alcançado com as simulações foi maior que o do ciclo cascata: 1,690 contra 0...

‣ Otimização termoeconomica de sistemas de refirgeração do processo de produção de etileno e propileno; Thermoeconomic optimization of refrigeration systems of the production process of ethylene and propylene

Francine de Mendonça Fabrega
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 16/03/2010 Português
Relevância na Pesquisa
37.220156%
A indústria petroquímica é o setor industrial que utiliza como matéria prima derivados do petróleo, principalmente a nafta petroquímica, da qual se produzem substâncias como o etileno e propileno. Nesse processo industrial utilizam-se ciclos de refrigeração de larga escala que fornecem utilidades frias ao processo, em especial aos condensadores das colunas de destilação e destacam-se por serem grandes consumidores de energia, sendo de extrema importância que estes ciclos operem de forma otimizada visando a redução de custos. A Quattor Unidade de Químicos Básicos Cracker ABC, localizada no Pólo Petroquímico de Capuava, em Santo André (SP) vem produzindo atualmente 700 mil t/ano de etileno, sendo umas das principais produtoras do setor. A fim de reduzir os custos de processos industriais, as análises exergética e exergoeconômica seguidas da otimização termoeconômica são ferramentas que têm sido empregadas com sucesso. Neste trabalho, com o objetivo de otimizar o sistema de refrigeração que produz as utilidades frias, foi utilizado o simulador comercial Hysys© versão 3.2 para a simulação do processo produtivo e do ciclo de refrigeração, obtendo-se as grandezas termodinâmicas necessárias para o cálculo da análise exergética. Aplicando a metodologia desenvolvida por Lozano e Valero (1993) foi possível calcular os custos de cada corrente do processo utilizando o software Matlab 7.0. A otimização do processo foi realizada utilizando-se a ferramenta Optimizer presente no próprio simulador. A função objetivo foi definida visando minimizar a exergia destruída no processo e o método de otimização utilizado foi o SQP (Sequential Quadratic Programing). Com a metodologia aplicada a exergia destruída foi reduzida em 19...

‣ Análise termodinâmica e otimização de um sistema de refrigeração por absorção para conservação de alimentos; Thermodynamic analysis and optimization of an absorption refrigeration system for food preservation

Nayra Reis do Nascimento
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 15/12/2011 Português
Relevância na Pesquisa
37.220156%
Sistemas de refrigeração têm diversas aplicações, como por exemplo: proporcionar conforto térmico através da climatização de ambientes; gerar utilidades frias para aplicações em processos industriais; conservação de alimentos, bebidas e produtos farmacêuticos, entre outros. Sistemas de refrigeração por absorção podem ser aplicados para obter níveis de refrigeração menor, utilizando fontes alternativas de energia, como por exemplo, a energia solar. Essa tecnologia pode ser implantada em regiões onde não há energia elétrica, como é o caso de boa parte do Estado do Amazonas. No entanto, nessa região, há um alto potencial de energia solar, pois é cortada pela Linha do Equador. Nesse trabalho, um ciclo de refrigeração por absorção capaz de ser acionado por energia solar, utilizando como fluidos refrigerante-absorvente NH3/H2O, R134a/DMF, (R134a+R32+R23)/DMF e (R134a+R32)/DMF, foi estudado visando sua aplicação para a conservação de alimentos de pequenas comunidades do Estado do Amazonas. Os ciclos foram simulados utilizando o simulador de processos Aspen Hysys®, versão 7.2. Uma vez validadas as simulações, foi realizada uma análise termodinâmica das principais variáveis operacionais (temperatura do gerador e do evaporador e pressão da região de baixa pressão) e em seguida...

‣ EXERGOECONOMIC COMPARISON OF ABSORPTION REFRIGERATION SYSTEMS INCLUDING A HIBRID ABSORPTION-EJECTO COMPRESSION CHILLER

BURBANO JARAMILLO,JUAN CARLOS; PELLEGRINI,LUIZ FELIPE; DE OLIVEIRA JR,SILVIO
Fonte: DYNA Publicador: DYNA
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2011 Português
Relevância na Pesquisa
37.220156%
The study of absorption refrigeration systems has had increasing importance in recent years due to the fact that the primary energy that is used in an absorption system can be heat available from a residual source or even a renewable one. Therefore, these systems not only use energy that would be rejected by the environment, but also they avoid the consumption of expensive fossil or electrical energies. The production cost of the mechanical work necessary to obtain a kW of refrigeration for mechanical compression cycle is normally higher than the cost for recovering the needed heat to obtain the same kW in an absorption cycle. Also, the use of these systems reduces impact on the environment by decreasing the emission of CO2. We intend to show the performance of a hybrid absorption-ejecto compression chiller compared to conventional double- and single-effect water/lithium bromide systems, by means of an exergetic and exergoeconomic analysis of these configurations in order to calculate the exergy-based cost of a final product. The vapor compression refrigeration system is included in the results, as a comparisson to the performance of the absorption refrigeration systems analyzed.

‣ An overview of refrigeration and its impact on the development in the Democratic Republic of Congo

Ituna-Yudonago,Jean Fulbert; Belman-Flores,J M; Pérez-García,V
Fonte: Journal of Energy in Southern Africa Publicador: Journal of Energy in Southern Africa
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2015 Português
Relevância na Pesquisa
37.350754%
The development of refrigeration is a priority in all countries, given the multidimensional roles that it plays in the sustainable development of society. In developing countries, efforts are being made to catch up with the delayed experienced in the use of refrigeration. To achieve this goal, several countries are allowed to trace the history of refrigeration in their countries in order to understand the main causes of non-expansion, and then set up a new strategy of sustainable development for this technology. The Democratic Republic of Congo (DRC) is a developing country that has experienced a very interesting history of refrigeration, but is still less known by the Congolese themselves as well as by scientists. This paper has traced out the outline in the history of refrigeration in the DRC. Surveys were conducted in the industrial, health, residential, commercial, and tourism sectors during the colonial and post-colonial period. Results showed that the use of refrigeration in the DRC has been remarkably observed in the industrial sector, especially in breweries, with a cooling capacity ranging from 50.1 thousand to 2.88 million kWh, about 5 659 % between 1929 and 1957; from 3 million to 26.5 million kWh, about 783.3 % between 1958 and 1980...